Arrow VD86 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Schneewerfer Arrow VD86 herunter. Arrow VD86 Instructions / Assembly Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Model No. VD86 697.68616
Owner's Manual & Assembly Instructions
W01
705340111
Exterior Dimensions Interior Dimensions Door
*Approx. Base (Roof Edge to Roof Edge) (Wall to Wall) Opening
Size Size Width Depth Height Width Depth Height Width Height
8' x 6' 97 1/2" x 68 3/4" 99 3/4" 71 1/4" 79 1/8" 94 3/4" 66" 77 7/8" 43 1/2" 69 1/4"
Storage Area: 43 Sq. Ft. 271 Cu. Ft.
4,0 m
2
7,7 m
3
BUILDING DIMENSIONS * Size rounded off to the nearest foot
2,4 m x 1,7 m 247,7 cm x 174,6 cm 253,4 cm 181,0 cm 201,0 cm 240,7 cm 167,6 cm 197,8 cm 110,5 cm 175,9 cm
CAUTION: SOME PARTS HAVE SHARP EDGES. CARE
MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES
TO AVOID A MISHAP. FOR SAFETY SAKE, PLEASE READ
SAFETY INFORMATION PROVIDED IN THIS MANUAL
BEFORE BEGINNING CONSTRUCTION. WEAR GLOVES
WHEN HANDLING METAL PARTS.
Missing Parts, Questions on Assembly?
Call: 1-800-851-1085 or
Do not return to dealer, they are not
equipped to handle your requests.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Model No. VD86 697.68616

Model No. VD86 697.68616Owner's Manual & Assembly Instructions W01705340111 Exterior Dime

Seite 2 - BEFORE YOU BEGIN

It is important that the entire floor frame be anchored after the building is erected.Below are recommended ways of anchoring. Anchoring Down The Buil

Seite 3 - PLAN AHEAD

11Remove from bag of screwsand save for the last step67293Weather Stripping (1)66382Lower Door Guide (4)66183Roof Trim Cap(2 right & 2 left)67468

Seite 4 - SAFETY FIRST

12Parts ListW12 ctrAssembly Part Part Quantity CheckKey No. Number Description in Carton List 1 8941 Ramp 1 2 9379 Front Floor Frame 2 3 9377 Rear

Seite 5 - CARE & MAINTENANCE

13Assembly by Key No. W13 ctr

Seite 6 - ACCESSORIES

The front floor frame is made up ofthree pieces. The rear floor frame ismade up of two pieces. The holes inthese pieces will align when thepieces are

Seite 7

Step 2W15 ctr15● Parts Needed For ●Frame AssemblyThe main frame pieces reinforce thewalls. This piece will later be installedat the top edge of the re

Seite 8

16Step 3B16 ctr● Parts Needed For ●Roof Beam Assembly●●●●● 8474 Roof Beam (1)●●●●● 8476 Side Wall Angle (1)The roof beams join the two gablesand suppo

Seite 9 - The Base For Your Building

17NOTE:Door Track Splice (painted part)Step 4B17 ctr● Parts Needed For ●Door Track Assembly●●●●● 6617 Door Track Splice (1)●●●●● 9378 Door Track (2)Th

Seite 10 - Anchoring

●●●●● Front Floor Assembly (1)●●●●● 8946 Side Floor Frame (2)●●●●● Rear Floor Assembly (1)● Parts Needed For ●Floor FrameStep 5B18 ctrThe floor frame

Seite 11 - Hardware

1 Position corner posts at the cor-ner of the floor frame as shown. Fas-ten the corner post to the floor framewith two screws.Support the corner post

Seite 12 - Parts List

Owner's ManualBefore beginning construction, check local building codes regarding footings, locationand other requirements. Study and understand

Seite 13 - Assembly by Key No

The door jambs reinforce the dooropening and provide an attractivetrim. The splice post supports therear wall.1 Position splice post at the centerof

Seite 14 - Floor Frame Assemblies

The studs provide a surface for at-taching the siding panels.1 Following dimensions, measuringfrom the ends of angles, place a studbetween each corner

Seite 15 - Frame Assembly

Each screw in the wall requires awasher.1 Slide side siding into channelsof corner posts, flat edge upward,bottom edge down resting on floorframe. A

Seite 16 - Roof Beam Assembly

1 Slide rear siding into channel ofcorner and splice posts fastening torear frame as shown in previous step.2 Install rear siding to completeeach se

Seite 17 - Door Track Assembly

24The gables go on top of the front andrear walls to support the roof beams.NOTEThe gables are packed nestedtogether and might be mistakenas one piece

Seite 18 - Floor Frame

1 Lift and fasten a right and leftgable, under angle at corner, to therear wall angle with screws.Hint: On the rear gable, use a boltand nut at the

Seite 19

1 Fasten the main roof beam to thegable brace of the front gable.2 Fasten the other end of the mainroof beam to the gable brace of therear gable.3 Fas

Seite 20 - Splice Post/Door Jamb

27Step 14W27 ctr● Parts Needed For ●Right Roof Panel●●●●● 8466 Right Roof Panel (1)Installing the roof panels is best donewith a step ladder. Begin i

Seite 21 - ● Parts Needed For ●

1 Install a left roof panel at the leftrear and right front corner of the roof.Install a right roof panel at the leftfront corner of the roof.2 Cut 2

Seite 22

1 Install the ridge cap on the com-pleted roof section using bolts. Donot fasten the ends of the ridge capuntil instructed to do so.2 Fasten the low

Seite 23 - Rear/Front Siding

Selecting and Preparing Your Site: Before assembly, you will want to decide ona location for your building. The best location is a level area with goo

Seite 24 - Gable Assemblies

30●●●●● 67725 Foam Board (2)●●●●● 10486 Right and Left Doors (2)●●●●● 10503 Horizontal Door Brace (4)●●●●● 8641 Vertical Door Brace (2)● Parts Ne

Seite 25 - Gables/Braces

31Step 18Y31 ctr● Parts Needed For ●Door Installation & Adjustment●●●●● Right Door Assembly (1)●●●●● Left Door Assembly (1)1 From inside the build

Seite 26 - Roof Beams

705340111VD86 697.68616 W32SOME FACTS ABOUT RUSTRusting is a natural oxidizing process that occurswhen bare metal is exposed to moisture. Problemare

Seite 27 - Right Roof Panel

Safety precautions are important to follow throughout the construction of your building.•Care must be taken when handling variouspieces of your buildi

Seite 28 - Roof Assembly

Finish: For long lasting finish, periodically clean and wax the exterior surface. Touch-up scratches as soon as you notice them on your unit. Immedia

Seite 29

ACCESSORIES... A6 WEB* Some drilling required to fit buildings without mid-wall bracing.Model No. SS404• Makes 8" to 12" (20,3-30,5 cm

Seite 30 - Door Brace

THIS PAGEWA SLEFTBLANKINTENTIONALLY7

Seite 31

THIS PAGEWA SLEFTBLANKINTENTIONALLY8

Seite 32 - Anchoring and Floor Frame

68 3/4"174,6 cmThe Base For Your Building9FRONT(DOOR)FRONT(DOOR)Base B09 ctr16"/24"40,6 cm/61,0 cmOPTION 1: ARROW FLOOR FRAME KIT:

Kommentare zu diesen Handbüchern

Keine Kommentare