Arrow NP10867 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Nein Arrow NP10867 herunter. Arrow NP10867 Instructions / Assembly Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
* Size rounded off to the nearest foot
BUILDING DIMENSIONS
CAUTION: SOME PARTS HAVE SHARP EDGES. CARE
MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES
TO AVOID A MISHAP. FOR SAFETY SAKE, PLEASE READ
SAFETY INFORMATION PROVIDED IN THIS MANUAL
BEFORE BEGINNING CONSTRUCTION. WEAR GLOVES
WHEN HANDLING METAL PARTS.
709431009
Model No. HM10867 NP10867 RM108-A
RMG108 RMW108 VH108-A
WL10867
Owner's Manual & Assembly Instructions
V01
Exterior Dimensions Interior Dimensions Door
*Approx. Foundation Storage Area (Roof Edge to Roof Edge) (Wall to Wall) Opening
Size Size Sq. Ft. Cu. Ft. Width Depth Height Width Depth Height Width Height
10' x 8' 121" x 92 3/4" 74 444 123 1/4" 95 1/4" 77 7/8" 118 1/4" 90" 76 5/8" 55 1/2" 65"
3,0 m x 2,3 m 307,3 cm x 235,6 cm 6,9 m
2
12,6 m
3
313,1 cm 241,9 cm 197,8 cm 300,4 cm 228,6 cm 194,6 cm 141,0 cm 165,1 cm
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - WL10867

* Size rounded off to the nearest footBUILDING DIMENSIONSCAUTION: SOME PARTS HAVE SHARP EDGES. CAREMUST BE TAKEN WHEN HANDLING THE VARIOUS PIECESTO AV

Seite 2 - BEFORE YOU BEGIN

It is important that the entire floor frame be anchored after the building is erected.Below are recommended ways of anchoring. Anchoring Down The Buil

Seite 3 - PLAN AHEAD

11Remove from bag of screwsand save for the last step67293Weather Stripping (1)5971Roof Beam Bracket (4)66382Lower Door Guide (4)66183Roof Trim Cap(2

Seite 4 - SAFETY FIRST

Parts List V1212Assembly Part Part Quantity CheckKey No. Number Description in Carton List 1 3719 Door Handle Brace 2 2 8200 Wall Pane

Seite 5 - CARE & MAINTENANCE

13Assembly by Key No.A13112222334455667788889910111212121212121313141415161717171718181919202021212222232424242424242424252526262626272727272829303031

Seite 6 - ACCESSORIES

The front floor frame is made up ofthree pieces. The side floor framesand the rear floor frame are made upof two pieces. The holes in thesepieces will

Seite 7

Step 2A1515● Parts Needed For ●Frame AssembliesThe main frame pieces reinforce thewalls. These pieces will later be in-stalled in the center and at th

Seite 8

16The roof beams join the two gablesand support the roof panels. The mainroof beam is made up of four piecesoverlapped back to back at the cen-ter. Th

Seite 9 - Foundation

17NOTE:Door Track Splice (painted part)Step 4A17● Parts Needed For ●Door Track Assembly●●●●● 6403 Door Track Splice (1)●●●●● 9366 Door Track (2)66769S

Seite 10 - Anchoring

●●●●● Front Floor Assembly (1)●●●●● Side Floor Assembly (2)●●●●● Rear Floor Assembly (1)● Parts Needed For ●Floor FrameStep 5A18The floor frame must b

Seite 11 - Hardware

1 Position a corner panel at thecorner of the floor frame as shown.The widest part of each corner panelmust be placed along the side of thebuilding f

Seite 12 - Parts List

2Owner's ManualBefore beginning construction, check local building codes regarding footings, locationand other requirements. Study and understand

Seite 13 - Assembly by Key No

The main frame pieces give rigidity tothe side walls and provide a surfacefor attaching the gables which sup-port the roof.1 Fasten the rear wall ang

Seite 14 - Floor Frame Assemblies

Step 8V21● Parts Needed For ●Wall Panels●●●●● 8200 Wall Panel (4)●●●●● 6627 Wall Panel (4)The wall panels come in two widths.Each wall panel has a cri

Seite 15

●●●●● 9370 Door Jamb (2)●●●●● 9365 Front Wall Channel (2)● Parts Needed For ●Front Channel/Door JambStep 9U22The door jambs reinforce the dooropening

Seite 16 - Roof Beam Assemblies

23The gables go on top of the front andrear walls to support the roof beams.NOTEThe gables are packed nestedtogether and might be mistakenas one piece

Seite 17 - 2 Insert four screws

● Parts Needed For ●Gables/BracesStep 11A24●●●●● Left Gable Assemblies (2)●●●●● Right Gable Assemblies (2)●●●●● 6635 Gable Brace (2)241 Lift and fast

Seite 18 - Floor Frame

25Step 12A25● Parts Needed For ●Roof Beams●●●●● Main Roof Beam (1)●●●●● Single Roof Beam (2)1 Spread the two halves of the mainroof beam and fasten th

Seite 19 - ● Parts Needed For ●

26Step 13A26● Parts Needed For ●Right Roof Panel●●●●● 8468 Right Roof Panel (1)Installing the roof panels is best donewith a step ladder. Begin insta

Seite 20 - Building

1 Install a left roof panel at the leftrear and right front corner of the roof.Install a right roof panel at the leftfront corner of the roof.3 Instal

Seite 21

28Step 15A28● Parts Needed For ●Ridge Caps & Panels●●●●● 8840 Ridge Cap (1)●●●●● 7483 Roof Panel (2)●●●●● 8486 Ridge Cap (1)1 Install the first ri

Seite 22 - Front Channel/Door Jamb

1 Attach the right and left side rooftrim to the lower end of the roof pan-els on each side of the building usingscrews at each panel overlap.NOTEA si

Seite 23 - Gable Assemblies

3Selecting and Preparing Your Site: Before assembly, you will want to decide ona location for your building. The best location is a level area with go

Seite 24 - Gables/Braces

30●●●●● 3719 Door Handle Brace (2)●●●●● 10477 Right and Left Doors (2)●●●●● 10497 Horizontal Door Brace (4)●●●●● 6300 Vertical Door Brace (2)● Par

Seite 25 - Roof Beams

31Step 18A31● Parts Needed For ●Door Installation & Adjustment●●●●● Right Door Assembly (1)●●●●● Left Door Assembly (1)1 From inside the building,

Seite 26 - Right Roof Panel

10193 510192 210196 210193 10193 101931019310193101931019210192101921019210194101941019610196Assembly ManualFB109-A 697.68385-A

Seite 27 - Roof Assembly

1. Before assembling this kit, the floor frames packed with the building must be assembled.• Vor dem Zusammenbau dieses Bausatzesmüssen die mit dem G

Seite 28 - Ridge Caps & Panels

10 x 7, 10 x 8, 10 x 9 & 10 x 104. Frame must be square and level.• Montieren Sie über lappende Teile.• Ensamble las piezas que solapan.• Assemb

Seite 29 - Roof Trim

Installing Plywood8 x 8Sheet #322 1/8“x 87 3/4”Sheet #148“ x 87 3/4”Platte 1 * Hoja núm. 1* Panneau no 1121.9 cm x 222.9 cmSheet #248“ x 87 3/4”Platt

Seite 30 - Door Brace

SOME FACTS ABOUT RUSTRusting is a natural oxidizing process that occurswhen bare metal is exposed to moisture. Problemareas include screw holes, unfin

Seite 31

4Safety precautions are important to follow throughout the construction of your building.•Care must be taken when handling variouspieces of your build

Seite 32 - FB109-A 697.68385-A

Finish: For long lasting finish, periodically clean and wax the exterior surface. Touch-up scratches as soon as you notice them on your unit. Immedia

Seite 33 - Assembly

ACCESSORIES... A6 WEB6* Some drilling required to fit buildings without mid-wall bracing.Model No. SS404• Makes 8" to 12" (20,3-30,5 c

Seite 34 - Plywood Requirements

THIS PAGEWA SLEFTBLANKINTENTIONALLY7

Seite 35 - Installing Plywood

THIS PAGEWASLEFTBLANKINTENTIONALLY8

Seite 36 - 709431009

The Foundation For Your Building9FRONT(DOOR)FRONT(DOOR)Foundation A09Note: Finished Slab dimensions, with lumber removed.OPTION 1: ARROW FLOOR FRA

Kommentare zu diesen Handbüchern

Keine Kommentare